Things to keep in mind when ordering a Rohn RT Tower Kit:
Items That ARE Included
Optional Items That ARE NOT Included
ANSI/TIA-222-G
TOWER HEIGHT (FT) | TOWER KIT P/N | ALLOWABLE EFFECTIVE PROJECTED AREA (FT2) | |||||||||||
ULTIMATE WIND SPEED WITHOUT ICE (MPH) | |||||||||||||
EXPOSURE | 85 | 90 | 95 | 100 | 105 | 110 | 115 | 120 | 130 | 140 | 150 | ||
190 | RT190L | C | 93 | 72 | 54 | 32 | 13 | - | - | - | - | - | - |
B | 138 | 112 | 90 | 71 | 55 | 40 | 22 | 6 | - | - | - | ||
RT190M | C | 186 | 160 | 137 | 118 | 101 | 86 | 74 | 53 | 7 | - | - | |
RT190H | C | 250 | 250 | 248 | 222 | 200 | 176 | 150 | 118 | 66 | 24 | - | |
180 | RT180L | C | 70 | 51 | 34 | 19 | - | - | - | - | - | - | - |
B | 113 | 90 | 69 | 52 | 37 | 24 | 11 | - | - | - | - | ||
RT180M | C | 188 | 162 | 142 | 125 | 109 | 93 | 76 | 61 | 20 | - | - | |
RT180H | C | 250 | 250 | 237 | 211 | 189 | 169 | 147 | 128 | 79 | 35 | - | |
170 | RT170L | C | 74 | 53 | 34 | 19 | 5 | - | - | - | - | - | - |
B | 123 | 97 | 74 | 55 | 39 | 24 | 12 | - | - | - | - | ||
RT170M | C | 192 | 165 | 142 | 122 | 105 | 91 | 72 | 48 | 9 | - | - | |
RT170H | C | 250 | 250 | 250 | 228 | 205 | 182 | 157 | 128 | 75 | 33 | - | |
160 | RT160L | C | 76 | 56 | 39 | 25 | 12 | - | - | - | - | - | - |
B | 122 | 98 | 77 | 59 | 43 | 30 | 18 | 8 | - | - | - | ||
RT160M | C | 193 | 168 | 147 | 129 | 113 | 98 | 81 | 58 | 20 | - | - | |
RT160H | C | 250 | 250 | 244 | 217 | 194 | 175 | 157 | 141 | 89 | 45 | - | |
150 | RT150L | C | 81 | 59 | 40 | 24 | 10 | - | - | - | - | - | - |
B | 135 | 107 | 84 | 64 | 47 | 32 | 19 | 8 | - | - | - | ||
RT150M | C | 199 | 171 | 147 | 126 | 104 | 85 | 68 | 50 | 19 | - | - | |
RT150H | C | 250 | 250 | 250 | 234 | 211 | 180 | 153 | 129 | 80 | 43 | 9 | |
140 | RT140L | C | 83 | 62 | 45 | 30 | 17 | 6 | - | - | - | - | - |
B | 133 | 108 | 86 | 67 | 51 | 37 | 25 | 15 | - | - | - | ||
RT140M | C | 200 | 174 | 152 | 134 | 113 | 90 | 70 | 52 | 23 | - | - | |
RT140H | C | 250 | 250 | 250 | 224 | 201 | 178 | 153 | 129 | 84 | 49 | 20 | |
130 | RT130L | C | 90 | 67 | 47 | 31 | 17 | 5 | - | - | - | - | - |
B | 147 | 118 | 94 | 74 | 56 | 41 | 27 | 15 | - | - | - | ||
RT130M | C | 200 | 179 | 154 | 133 | 115 | 100 | 78 | 59 | 27 | - | - | |
RT130H | C | 250 | 250 | 243 | 215 | 191 | 171 | 152 | 137 | 95 | 56 | 25 | |
120 | RT120L | C | 91 | 69 | 52 | 36 | 23 | 12 | - | - | - | - | - |
B | 146 | 119 | 96 | 77 | 60 | 46 | 33 | 22 | - | - | - | ||
RT120M | C | 168 | 145 | 126 | 109 | 94 | 82 | 68 | 55 | 33 | 10 | - | |
RT120H | C | 250 | 250 | 250 | 233 | 208 | 187 | 158 | 131 | 86 | 51 | 22 | |
110 | RT110L | C | 121 | 98 | 78 | 61 | 46 | 33 | 22 | 12 | - | - | - |
B | 150 | 150 | 128 | 106 | 88 | 71 | 57 | 45 | 24 | - | - | ||
RT110M | C | 200 | 187 | 162 | 140 | 121 | 101 | 83 | 67 | 42 | 22 | - | |
RT110H | C | 250 | 250 | 250 | 223 | 199 | 178 | 160 | 142 | 112 | 79 | 44 | |
100 | RT100L | C | 116 | 94 | 76 | 60 | 47 | 35 | 25 | 16 | - | - | - |
B | 150 | 147 | 123 | 103 | 86 | 71 | 57 | 46 | 27 | - | - | ||
RT100M | C | 173 | 150 | 130 | 113 | 98 | 85 | 74 | 61 | 39 | 21 | - | |
RT100H | C | 250 | 250 | 239 | 211 | 187 | 167 | 148 | 133 | 106 | 79 | 48 | |
The tabulated allowable effective projected areas (EPA) are limited to maximum recommended values of 150, 200 and 250 ft2 for the Light (L), Medium (M) and Heavy(H) series tower kits respectively. EPA values shown as “-“ indicate tower kit is not recommended for the corresponding wind speed. A site-specific engineering analysis is required for higher EPA or wind speed values. All Drop Shipped Orders from ROHN Factory are subject to your local and state sales tax. |